Hot water carries energy, and steam carries more. Enthalpy is the number that says how much energy water or steam is carrying for every bit of its weight, counted from an agreed starting point: cold liquid water. Heat it at the same pressure and its enthalpy goes up by exactly the heat you put in. Let it spin a shaft of blades, which engineers call a turbine, and its enthalpy drops by exactly the work it gave. You never need the number on its own, only how much it changed.

A kettle with an energy gauge

Heat a kilogram of water

Turn up the heat added and watch the gauge, the thermometer and the water.

waterkettleheaterenergy meter0 kJthermometer20.00 °Ccold water20 °C, 84.01 kJ/kgat the boil419 kJ/kgzeroenthalpy
heat added to it
0 kJ
temperature
20 °C
share of vapor
0
the gauge reads
84.01 kJ/kg

Notice

The gauge fills exactly as the meter counts; the thermometer climbs to 100 °C, sticks while the water boils, then climbs again.

The thermometer missed about 2,257 kJ: the energy that turned the water to steam without warming it. The gauge did not. That gauge is enthalpy, the energy each kilogram of water or steam carries, and it is why temperature alone was not enough.

What is inside it

Lid locked or lid free

Flip the latch, then turn up the heat added and watch the two colors of the gauge.

water vaporliquid watercylinderpistonweightlatchlockedpressure gauge101.3 kPaheaterenthalpyenergy insidepushing room
heat added to it
0 kJ
pressure
101.3 kPa
temperature
99.97 °C
energy inside
421 kJ/kg
pushing room
0.2752 kJ/kg
enthalpy
421.2 kJ/kg
energy inside gained
0 kJ/kg

Notice

Locked: all the heat goes to energy inside and the pressure climbs. Free: the weight rises, the pressure holds, some goes to pushing room.

Enthalpy is the energy inside the water or steam plus the energy it took to push room for itself, its pressure times its volume. Two colors, one number.

Enthalpy is the energy inside, , plus the pushing room, times .

Only differences matter

Move the zero

Drag the zero line on the gauge up or down.

waterkettleheaterenergy meter0 kJthermometer20.00 °Ccold water20 °C, 84.01 kJ/kgat the boil419 kJ/kgzerothe gap335 kJ/kgenthalpy
zero set at
0.01 °C
cold water
84.01 kJ/kg
at the boil
419 kJ/kg
the gap
335 kJ/kg

Notice

Both numbers change as the zero moves; the gap between 20 °C and the boil never does.

The tables put zero at cold liquid water, at 0.01 °C. Another table could put it elsewhere and every answer would come out the same, because every answer is a difference.

Get its number

One row of the printed table

Slide the pressure and read the row: the water just boiling, and the steam just formed.

pkPaTsat°ChfkJ/kghfgkJ/kghgkJ/kg
1045.808191.812392.12583.9
2060.059251.42357.52608.9
5081.317340.482304.72645.2
10099.606417.442257.52674.9
200120.21504.682201.62706.2
500151.84640.192107.92748.1
1000179.89762.682014.42777.1
2000212.38908.621889.82798.4
5000263.941154.51639.72794.2
100003111407.91317.62725.5
20000365.751827.1584.292411.4
03000 kJ/kghf  762.68hg  2777.1hfg  2014.4

The gap shortens as the pressure rises, and closes completely at the critical point, 22.06 MPa, where these tables stop.

Notice

Both ends come from the table; the gap shrinks as pressure rises and would close at about 22 MPa, which engineers call the critical point.

You read enthalpy from the tables; you do not calculate it. The only arithmetic is for wet steam, part water and part vapor, and the bar shows it.

Wet steam's enthalpy is the just-boiling water's, , plus the part already turned to steam, which engineers call its share of vapor, , times the gap, .

Where it shows up: the turbine

The turbine takes the drop

Drag state 2 down to lower the pressure the steam leaves at.

Temperature–entropy diagram. Rankine cycle from 10 MPa to 10 kPa: thermal efficiency 34.1%, back work ratio 1.09%, turbine exit quality 0.874.T–s diagramreal cycleideal (constant s)sketch, no table data01002003004005006000246810T (°C)s (kJ/kg·K)Sketch only: the steam tables used here stop at 350 °C, so the dome between there and the critical point is not table data.Real turbine: its end states joined by a straight line; the irreversible process between them is not a series of table states.Real pump: its end states joined by a straight line; the irreversible process between them is not a series of table states.Critical point (placed from IAPWS-95, not computed here)12s234condenser pressure
Condenser pressure
10 kPa
Work per kilogram
1093 kJ/kg
Share of vapor at the exit
0.874
Exit temperature
45.81 °C

Notice

The work is the drop in enthalpy from in to out, and it grows as the exit pressure falls.

On a steam problem enthalpy appears four times, once at each machine, and every answer is a difference of two of them.

Where it bites, and a check

"Enthalpy is the heat in the steam" is wrong twice: it also counts pushing room, and one value on its own means nothing, because where its zero sits is a choice.

Check: one kilogram of water at 20 °C, at one atmosphere, has an enthalpy of about 84 kJ/kg. You add 500 kJ at constant pressure. Predict its enthalpy, and whether any of it has boiled.

Answer: about 584 kJ/kg, and yes: boiling starts at ≈ 419 kJ/kg, so about (584 − 419) ÷ 2,257 ≈ 7 % of it is steam.

Words, symbols and units on this page

  • Pressure.

  • specific volumem^3/kgnot written yet

    The space each kilogram of fluid takes up.

  • A wet mixture of liquid and vapor, and how much of it is vapor.

  • saturated liquidnot written yet

    Water that is all liquid and right at its boiling point.

  • saturated vapornot written yet

    Steam that is all vapor and right at its boiling point.

  • The tables that give the properties of water and steam.

  • Water turning to steam under a steady pressure, its temperature held while it boils.

  • Energy per kilogram.

  • How expanding steam produces shaft work.

  • workkJ/kgnot written yet

    The energy a machine gives out through its shaft, or takes in.

  • statenot written yet

    Where the fluid is in the loop, fixed by two of its properties.