Skip to the content
Steam cycle · Concept

Water turns to steam · Boiling at constant pressure

In plain words

Put water in a cylinder with a weight on top and heat it. The water warms until it boils, and then its temperature stops rising even though you keep heating: all the heat is going into turning liquid into steam. The weight keeps the pressure the same the whole time. Only when every drop has become steam does the temperature climb again. This is what the boiler of a power plant does to its water.

Heat it, and watch

Heat it on a timeline

Drag along the timeline to add heat, or tap a snapshot to jump to it.

water vaporliquid waterpistonweightscylinderthermometer20.0 °Cshare of vapornoneallheaterheat in
boiling starts
last drop

temperature
20 °C
share of vapor
0
volume of the kilogram
0.001002 m³
volume, times the start
1
heat added to it
0 kJ
enthalpy
84.01 kJ/kg
heat to boil it all
2257 kJ

Notice

The thermometer climbs, then holds while the water turns all to steam and the piston rises, then climbs again.

The temperature holds because every kilojoule is busy pulling water molecules apart into steam, not speeding them up. From the first bubble to the last drop, the kilogram's volume grows about 1,600 times.

The same run on the chart

In step on the chart

Drag the timeline and watch the dot on the temperature–entropy chart.

water vaporliquid waterpistonweightscylinderthermometer20.0 °Cshare of vapornoneallheaterheat in
010020030040002468entropy (kJ/kg·K)temperature (°C)critical pointwet mixturevaporstate
boiling starts
last drop

temperature
20 °C
share of vapor
0
volume of the kilogram
0.001002 m³
volume, times the start
1
heat added to it
0 kJ
enthalpy
84.01 kJ/kg
heat to boil it all
2257 kJ

Notice

The dot climbs the left edge, runs flat across the dome while the thermometer holds, then climbs on the right.

The flat stretch is the boiling. Its length, in heat, is the energy that boils one kilogram all the way, .

The heat that turns a kilogram of just-boiling water into dry steam is the energy the steam carries minus the energy the water carried.

The weight held fixed

More weights, more pressure

Slide the weights up or down to change the pressure, and compare this run with the one at one atmosphere.

water vaporliquid waterbubblespistonweightscylinderthermometer100.0 °Cshare of vapornoneallheaterheat in
010020030040002468entropy (kJ/kg·K)temperature (°C)critical pointwet mixturevaporstatethis runone atmosphere
pressure
101.3 kPa
boiling temperature
99.97 °C
heat to boil it all
2257 kJ

At the critical point, about 22 MPa, the flat stretch would close to nothing. The steam tables here stop short of it, so this page cannot draw that far.

Notice

More pressure boils hotter and makes the flat stretch shorter; at about 22 MPa it would close to nothing.

"At constant pressure" is the rule of this run. Change the pressure and you get a different run, with a different flat stretch.

Backwards: condensing

Run it backwards

Start from dry steam and drag the timeline back to take the heat out.

water vaporpistonweightscylinderthermometer200.0 °Cshare of vapornoneallheaterheat in
010020030040002468entropy (kJ/kg·K)temperature (°C)critical pointwet mixturevaporstate
boiling starts
last drop

temperature
200 °C
share of vapor
1
volume of the kilogram
2.144 m³
volume, times the start
2140
heat added to it
2791 kJ
enthalpy
2875 kJ/kg
heat to boil it all
2257 kJ

Notice

The steam turns back to water at the same temperature, the piston sinks, and the dot runs the flat stretch right to left.

Condensing is boiling in reverse, and it gives back the same energy. The condenser of a power plant runs this stretch backwards, at a much lower pressure.

Where it happens in the plant

entropytemperaturecritical pointliquidwet mixturevaporfirstsecondthirdboilercondenser
The steam cycle on a temperature–entropy chart, with the boiler's leg (state 4 to state 1) and the condenser's leg (state 2 to state 3) lit.

Most of the boiler's heat goes in along the flat stretch, forwards; most of the condenser's comes out along it, backwards.

Where it bites, and a check

Adding heat does not always raise the temperature. A thermometer in boiling water at one atmosphere reads about 100 °C however hard the fire burns; the heat is still going in, and it is making steam.

Check: at 200 kPa water boils at about 120 °C, and one kilogram takes about 2,202 kJ to turn fully to steam. You add 1,000 kJ to one kilogram that has just started to boil. Predict its temperature and the share that is steam.

Answer: still about 120 °C, and about 0.45 of it is steam, since 1,000 ÷ 2,202 ≈ 0.45.

Words, symbols and units on this page

  • Pressure.

  • The energy a flowing kilogram of fluid carries.

  • entropykJ/kg·Knot written yet

    How spread out a fluid's energy is; a perfect machine keeps it the same.

  • A wet mixture of liquid and vapor, and how much of it is vapor.

  • saturated liquidnot written yet

    Water that is all liquid and right at its boiling point.

  • saturated vapornot written yet

    Steam that is all vapor and right at its boiling point.

  • superheated vapornot written yet

    Steam heated past its boiling point, all vapor and hotter than it needs to be.

  • specific volumem^3/kgnot written yet

    The space each kilogram of fluid takes up.

  • Where heat turns liquid water into steam.

  • condensernot written yet

    Where exhaust steam gives up heat and becomes liquid.

  • statenot written yet

    Where the fluid is in the loop, fixed by two of its properties.

  • The tables that give the properties of water and steam.